نوشته شده توسط : Mens Socks Suppliers

Physical securing. Backbone cables must have standard imposed fire rating specifications. On each floor, a telecom room concentrates all workstation cables for that floor. These backbone cablings typically are done from floor to floor to floor. :: Horizontal Cabling The horizontal wires, which run from workstations on the same floor to the telecom room, are then terminated on punchdown termination, or directly onto a patch panel. :: What do we do to observe the 100 meters wiring standard? In order to achieve the wiring concentration standard, telecommunication rooms (wiring centers) are placed at planned locations in a building. At one same corner of each floor, a telecom rooms is constructed; these telecom rooms are then connected by backbone wiring (cables run vertically through the floors and link all telecom rooms together). With today�s high speed networks, people realize that the networking system must be broken up into shorter chunks that allow workstation wiring to be concentrated, with each cable length short enough to support the high data rate. Based on aforementioned reasons, structured wiring Toe Socks Factory in China standard has been developed to help define a computer wiring system that stays within the maximum wiring distance for various LAN topologies. Physical securing for vertical riser cables is also different than horizontal cables. For larger floors, more than one telecom room may be needed. :: The difference between backbone cabling and horizontal cabling Since backbone cabling typically passes through from floor to floor, the cables used for backbone cabling have very different requirement than the horizontal cablings. The network cable is terminated at that jack and runs directly to the telecom room. Typically this is OFNR (Optical Fiber Non-Conductive Riser) rated. :: What is structured cabling? Modern computer LAN (local area network) wiring has the concept of structured cabling. For example, the horizontal cable wiring length is 100 meters for 100BaseT networks. So is the cable strength, since vertical riser cables need to have enough strength to support its own weight. 1. The punchdown terminations or patch panels could be rack mounted (19 or 23 racks), cabinet mounted or wall mounted.. These telecom rooms are then interconnected to provide the total network connectivity for the building. Another advantage of fiber is that fibers can run much longer distance than copper cable, which makes them especially attractive for backbone cabling. :: Vertical Cabling (Backbone Cabling) Telecom rooms on each floor are then connected together by backbone cabling (also called vertical cabling for floor to floor connections). With the emerge of Gigabit Ethernet and 10 Gigabit Ethernet, fiber optic cable is the most appropriate choice for backbone cabling since they provide much higher bandwidth than traditional Cat5, Cat6 or even Cat7 twisted pair copper cables. 2. The hub or switch then passes the computer signal on to other work stations or servers, or even to other telecom rooms for ultimate connectivity with the entire network. If the backbone cable passes through plenum area (spaces in the building used for air return in air conditioning), the cable must be OFNP (Optical Fiber Non-conductive Plenum) rated. Each workstation has a wall mounted jack. In the telecom room, network equipment such as a hub or switch is connected to each station cable, which electrically terminates the cable run. This can be explained in a three stories building. The cable may run in wire trays or conduit, or be draped over supports such as a drop ceiling. Usually telecom rooms should be located directly above one another in order to minimize the cable runs length, but this also varies from building to building. Fire ratings.



:: موضوعات مرتبط: cheap cycling socks , ,
:: برچسب‌ها: winter cycling socks,fun toe socks ,
:: بازدید از این مطلب : 148
|
امتیاز مطلب : 0
|
تعداد امتیازدهندگان : 0
|
مجموع امتیاز : 0
تاریخ انتشار : چهار شنبه 14 خرداد 1399 | نظرات ()

صفحه قبل 1 صفحه بعد